OVERVIEW |
Detector Type |
Focal plane array (FPA), uncooled microbolometer |
Focal Length |
9 mm (0.35 in.) |
IR Resolution |
320 × 240 pixels |
Languages |
English |
Material |
PPSU Silicon rubber Aluminium, cast Flame-resistant magnesium alloy |
Packaging Size |
500 × 190 × 370 mm (19.7 × 7.5 × 14.6 in.) |
Pitch |
25 µm |
Report Generation |
Separate software (FLIR Tools |
Set-up Commands |
Local adaptation of units, date and time formats |
Spectral Range |
7.5–13 µm |
Tripod Mounting |
UNC ¼"-20 (adapter needed) |
Zoom |
2× digital zoom |
Compatible with FLIR software |
FLIR Tools® |
CONNECTIONS & COMMUNICATIONS |
Interface |
Update from PC devices Data transfer to and from PC |
Storage Media |
Internal flash memory |
USB |
USB Mini-B |
ENVIRONMENTAL |
Directives |
Designed to meet NFPA 1801:2018 specification: Vibration Impact acceleration resistance Corrosion Viewing surface abrasion Heat resistance Heat and flame Product label durability |
Drop |
2 m (6.6 ft.) on concrete floor (IEC 60068-2-31) |
EMC |
EN 61000-6-2:2005 (Immunity) EN 61000-6-3: 2011 (Emission) FCC 47 CFR Part 15 B (Emission) |
Encapsulation |
IP 67 (IEC 60529) |
Humidity (Operating and Storage) |
IEC 60068-2-30/24 h 95% relative humidity 25°C to 40°C (77°F to 104°F) / 2 cycles |
Magnetic fields |
EN 61 000-4-8, Test level 5 for continuous field (severe industrial environment) |
Operating Temperature Range |
–20°C to 85°C (–4°F to 185°F) 150°C (302°F): 15 min. 260°C (500°F): 5 min. |
Relative Humidity |
95% relative humidity 25°C to 40°C (77°F to 104°F) non-condensing |
Shock |
25 g (IEC 60068-2-27) |
Storage Temperature Range |
–40°C to +85°C (–40°F to +185°F) |
Vibration |
2 g (IEC 60068-2-6) |
IMAGING & OPTICAL |
Camera size (L x W x H) |
120 × 125 × 280 mm (4.7 × 4.9 × 11 in.) |
Camera weight incl battery |
1.1 ±0.05 kg (2.4 ±0.1 lb.) |
Contrast optimization |
Digital image enhancement using FSX |
Depth of Field |
0.84 m to infinity (33 in. to infinity) |
f-number |
1.25 |
Field of view (FOV) |
51° × 38° |
Focus |
Fixed |
Image Frequency |
60 Hz |
Image Modes |
IR image TI Basic fire-fighting mode Black-and-white fire-fighting mode Fire mode Search-and-rescue mode Heat detection mode Thumbnail gallery |
Non-radiometric IR video recording |
MPEG-4 to internal flash memory |
Non-radiometric IR video streaming |
Uncompressed colorized video using USB |
Spatial resolution (IFOV) |
2.8 mrad |
Storage Capacity |
200 files in total, with a maximum duration of 30 minutes. The total number of files is co-dependent on the number of saved images. |
MEASUREMENT & ANALYSIS |
Accuracy |
±4°C (±7.2°F) or ±4% of reading, for ambient temperature 10°C to 35°C (50°F to 95°F) |
Automatic Hot Detection |
Heat detection mode (the hottest 20% of the of scene is colorized) |
Isotherm |
Yes |
Object Temperature Range |
–20°C to 150°C (–4°F to 302°F) 0°C to 650°C (32°F to 1202°F) |
Spot Meter |
1.0 |
Thermal Sensitivity/NETD |
<30 mK @ 30°C (86°F) |
Meter Data |
Auto Range |
Yes, selectable on/off using FLIR Tools® |
Display |
4 in. LCD, 320 × 240 pixels, backlit |
POWER |
Battery capacity |
4.4 Ah, at 20°C to 25°C (68°F to 77°F) |
Battery operating time |
Approx. 4 hours at 25°C (77°F) ambient temperature and typical use |
Battery Type |
Li Ion |
Battery voltage |
3.6 V |
Battery weight |
0.152 kg (0.3 lb.) |
Charging system |
Battery is charged inside the camera 2-bay charger Optional In-truck charger |
Charging Temperature |
0°C to 45°C (32°F to 113°F) |
Charging Time |
2 h to 85% capacity, charging status indicated by LEDs |
Power Management |
Automatic shutdown and sleep mode |
Safety [power supply] |
CE/EN/UL/CSA/PSE 60950-1 |
Start Up Time |
<17 s. (IR image, no GUI) |
Start-up time from sleep mode |
<4 s. |
STORAGE MEDIA |
File Formats |
Standard JPEG |
Image Storage |
Standard JPEG; Image freeze: configurable |
Image Storage Capacity |
200 files in total. The total number of files is co-dependent on the number of saved video clips. |
Image Storage Mode |
IR only |