HT HP000ECL Eclipse AC/DC TRMS 1000A Clamp Meter w/Thermal Imager

ECLIPSE has been designed to measure AC/DC current up to 1000A, DC voltage up to 1500V and AC voltage up to 1000V in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/EN61010-1.

More info

HT HP000ECL Eclipse AC/DC TRMS 1000A Clamp Meter w/Thermal Imager
Roll over image to zoom Click image to expand
  • HT HP000ECL Eclipse AC/DC TRMS 1000A Clamp Meter w/Thermal Imager

ECLIPSE has been designed to measure AC/DC current up to 1000A, DC voltage up to 1500V and AC voltage up to 1000V in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/EN61010-1. The clamp is provided with a display with 6000 measuring spots with backlight and bargraph to allow for a simple reading even in poorly lit environments.

ECLIPSE also measures Resistance, Frequency, Capacitance and Temperature with K-type probe and infrared temperature with built-in thermal camera. The Bluetooth connection allows for the transfer of the saved snapshots by means of the dedicated App HTMercury.

Specifications
TRMS  
Current measuring range 1000A
AC/DC current AC+DC
AC/DC voltage 1000VAC/1500VDC
Leakage current External Clamp
Frequency  
Resistance and continuity test with buzzer  
Capacity  
Diode test  
Duty Cycle (%)  
Temperature with K-type probe  
AC/DC current with external clamp transducer
   
Inrush current measurement (INRUSH)  
Measurement category CAT IV 600V CAT III 1000V
Maximum diameter for clamp 40mm
Measuring counts 6000
Backlight  
Bargraph  
Autorange  
Auto power off  
Detection of AC voltage without contact  
Data HOLD function  
MIN/MAX function  
PEAK function  
Relative measurement  
Thermal imager  
Colour LCD display  
Internal memory for data saving  
Datalogger and Graph  
PC / Smartphone or Tablet interface Bluetooth
Power supply Li-ION battery
Size (LxWx H) (mm) 280x100x50
Weight in grams (batteries included) 505
IR sensor resolution 80x80
Temperature range 20 + 260°C / -4 + 500°F
Thermal sensitivity / NETD  
NETD <100mK
Spectrum range 8 + 14µm
IFOV 4.53mrad
Type of IR sensor UFPA
Frequency 50Hz
Field of view (FOV) 21° X 21°
Lens 7,5mm
Focus mode Fixed
3 cursors: Central, Min, Max.  
Color Palettes 5
Readings in °C, °F, °K  
Class 2 laser pointer  
Integrated white light illuminator  
Manual and automatic span Automatic
Standard format of saved images JPEG BMP
Recharging system External charging base
Battery operation time 8 hours
Provided external power supply 100/240VAC (50/60Hz)/ 12VDC
Operating temperature 5°C + 40°C
Operating humidity <80%RH
  -20°C + 60°C
Storage humidity <80%RH
Mechanical protection IP40