Fluke 107 ESP Palm-Sized Digital Multimeter, CAT III, 600 v

The Fluke 107 ESP is a compact, palm size easy-to-use digital multimeter made to fit the way you work.

More info

Fluke 107 ESP Palm-Sized Digital Multimeter, CAT III, 600 v
Roll over image to zoom Click image to expand
  • Fluke 107 ESP Palm-Sized Digital Multimeter, CAT III, 600 v

The Fluke 107 ESP is a compact, palm size easy-to-use digital multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool; small enough to fit in a shirt pocket yet tough enough to withstand daily use, including a 1-meter drop test. For everyday applications where true-rms accuracy isn’t needed, the Fluke 107 delivers reliable measurements time after time. With a CAT III 600 V safety rating, you don’t need to compromise safety. The Fluke 107 ESP offers a comfortable grip, weighs only 200 g, and is easy to carry.

Features: 

  • Enabled with current and voltage measurement functions, in a compact size
  • Measures resistance & continuity to check for broken wires
  • Data hold and backlit display to keep you working safe and fast
  • Ergonomic and rugged
  • Comfortable grip, only weighs 200g and easy to carry
  • Rugged enclosure and 3.3' (1 m) drop test
  • Full-parameter automatic range test, which is convenient and quick to test; at the same time, it reduces the number of rotations of the wave plate and prolongs the life of the instrument
  • 6000-word large screen LCD backlight display
  • Battery powered, automatic power save mode
  • Data retention feature makes it easier to read measurement results
  • Compliant with IEC61010-1 CATIII 600V overvoltage protection safety standard

Test Functions: 

  • AC and DC voltage
  • AC and DC current
  • Resistance
  • Capacitance
  • Diode
  • Frequency and duty-cycle

What's In The Box: 

  • Fluke 107 palm-sized digital multimeter
  • (1 pair) TL75 Hard Point™ Test Leads
  • (2) AAA batteries (installed)
  • SmartStrap™ intelligent magnetic, multi-purpose lanyard
  • 1-year warranty.
Precision specifications
AC voltage
(40 Hz to 500 Hz)1
Range Resolution Accuracy
6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
1.0 % + 3
DC voltage 6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5 % + 3
Exchange millivolts 600.0 mV 0.1 mV 3.0 % + 3
Diode test2 2.000 V 0.001 V 10 %
Resistance
(ohm)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3
Capacitor3 50.00 nF
500.0 nF
5.000 μF
50.00 μF
500.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency4 Hz
(10 Hz – 100 kHz)
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
0.1 % + 3
Duty cycle4 1 % to 99 % 0.10 % 1 % typical case5
AC current
(40 Hz - 200 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
DC 4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
  1. All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.
  2. Typically, the open circuit test voltage is 2.0 V and the short circuit current is < 0.6 mA.
  3. The parameters do not include errors due to test lead capacitance and capacitor substrate (up to 1.5 nF in the 50 nF range).
  4. All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.
  5. Typically, the frequency is 50 Hz or 60 Hz and the duty cycle is 10% to 90%.
Features Overload protection Input impedance (nominal value) Common mode rejection ratio Normal mode rejection ratio
AC voltage 600 V 1 >10 MΩ <100 pF 2 >60 dB at 50 Hz or 60 Hz at DC current
Exchange millivolts 600 mV >1M, <100 pF >80 dB at 50 Hz or 60 Hz
DC voltage 600 V 1 >10 MΩ <100 pF >100 dB at 50 Hz or 60 Hz at DC current >60 dB at 50 Hz or 60 Hz
  1. Up to 6 x 105 V Hz
  2. For medium voltage (alternating current), the input impedance is approximately 1 MΩ.
General Technical Indicators
The highest voltage applied to any terminal and ground 600 V
Display (LCD) 6000 counts, updated three times per second
Type of battery Two AAA batteries (NEDA 24A, IEC LR03)
Battery life At least 200 hours
Temperature
Operating temperature 0 °C to 40 °C
Storage temperature -30 °C to 60 °C
Relative Humidity
Working humidity No condensation below 10 °C
≤ 90 % at 10 °C to 30 °C; ≤ 75 % at 30 °C to 40 °C
Working humidity, 40 MΩ range ≤ 80 % at 10 °C to 30 °C; ≤ 70 % at 30 °C to 40 °C
Altitude
Working elevation 2000 m
Storage altitude 12,000 m
Temperature coefficient 0.1 X (specified accuracy) / °C (<18 °C or >28 °C)
Current input fuse protection 11A, 1000V fast-melting type, must use Fluke designated parts
Volume (height x width x length) 142 mm x 69 mm x 28 mm
Weight 200 g
Protection level IEC 60529: IP 40
Safety IEC 61010-1: 600 V CAT III, pollution degree 2
Electromagnetic environment IEC 61326-1: Portable
Electromagnetic compatibility Applicable only in Korea. Class A equipment (industrial broadcasting and communication equipment)1
1 This product meets the requirements of industrial (Class A) electromagnetic wave equipment, which should be noted by the seller or user. The device is suitable for use in a work environment, not a home environment.