Electrical Specifications |
DC Voltage |
Range |
0.1 mV to 1000 V |
Accuracy |
±(0.05% + 1) |
Maximum resolution |
0.1 mV |
AC Voltage |
Range |
0.1 mV to 1000 V |
Accuracy |
±(0.7% + 4) true-rms |
AC bandwidth |
20 kHz with low pass filter; 3 dB @ 1 kHz |
Maximum resolution |
0.1 mV |
DC Current |
Range |
0.1 μA to 10 A (20 A for 30 seconds maximum) |
Amps accuracy |
±(0.2% + 2) |
Maximum resolution |
0.1 µA |
AC Current |
Range |
0.1 μA to 10 A (20 A for 30 seconds maximum) |
Amps accuracy |
±(1.0% + 2) true-rms |
Maximum resolution |
0.1 µA |
Resistance |
Range |
0.1 Ω to 50 MΩ |
Accuracy |
±(0.2% + 1) |
Maximum resolution |
0.1 Ω |
Capacitance |
Range |
0.01 nF to 9999 μF |
Accuracy |
±(1% + 2) |
Maximum resolution |
0.01 nF |
Frequency |
Range |
0.5 Hz to 199.99 kHz |
Accuracy |
±(0.005% + 1) |
Maximum resolution |
0.01 Hz |
Duty cycle |
Maximum duty cycle |
99.9% |
Accuracy |
±(0.2% per kHz + 0.1%) |
Maximum resolution |
0.1% |
Temperature measurement range |
–200.0 °C to 1090 °C –328.0 °F to 1994.0 °F excluding probe |
80 BK temperature probe |
–40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater –40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater |
Conductance |
Maximum conductance |
60.00 nS |
Accuracy |
±(1.0% + 10) |
Maximum resolution |
0.01 nS |
Diode test |
Range |
2 V |
Resolution |
0.001V |
Accuracy |
±(1% + 1) |
Diagnostics and data storage |
Peak Min/Max |
250 μS |
Min/Max/Avg |
Yes |
Reading hold/Auto (Touch) Hold |
Yes |
Relative reference |
Yes |
Display |
Digital |
6000 counts updates 4/second 19,999 counts in high–resolution mode |
Analog bar graph |
32 segments, updates 40/second |
Backlight |
Two level |
Low pass filter (VFD measurements) |
Yes |
Input Alert™ |
Yes |
Safety Specifications |
Safety rating |
IEC61010-1: Pollution Degree 2 IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V |
Agency approvals |
CE, CSA |
Mechanical and General Specifications |
IP rating |
IEC 60529: IP67 |
Power |
Three AA batteries. 800 hours typical, without backlight |
Size |
6.0 x 10.1 x 21.5 cm (with holster) |
Weight |
698.5 g (with holster) |
Warranty |
Limited lifetime |
Environmental Specifications |
Operating temperature |
-15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C |
Storage temperature |
-40 °C to + 60 °C |
Humidity (without condensation) |
0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C) |
Operating altitude |
2000 m |